SDS601 Sulphur Analyzer
 



Standard layout:
  SDS601 mainframe, Lenovo computer, laser printer 

Applicable Scope:
 It is applicable for the determination of total sulfur content of coal, coke, petroleum and other combustible materials.

Quality Certification:
  ASTM D 4239-2005

Standard Test Methods for Sulfur in the Analysis Sample of Coal and Coke Using High Temperature Tube Furnace Combustion Methods.

  GB/T214-2007 Determination of total sulfur in coal

Technical parameter:

Sulphur Determination Range

0.01%-35%

Furnace Working Temperature

1150℃ ( coal ) 900℃ ( oil )

Temperature Control Precision

± 2.5℃

Sample Weight

8-110mg

Sulphur Resolving Capability

0.01%

Test Time

3-6min/ 1 sample

Access Mode of the Samples

Auto

Sample Numbers

1

Air Flow Control Mode

Self Stabilization, without Adjusting

Precision

S t ≤1.5

Repeatability ≤0.05

S t :1.5~4.00

Repeatability ≤0.10

S t >4.00

Repeatability ≤0.20

Coal Addition

Incapable

Coal Queue-jump

Incapable

Air Tightness Checkout Gear

Yes

Air Pump

Steady air pump , no need replacing the plastic wrist

Max Power

3kW

Voltage

AC220±10 ﹪ 50Hz±1Hz

Mainframe Size

860×530×380mm

Weight

80kg


Main features:
The hardware integration working avoid the errors in the test results due to software integration so that the test results
  of high, medium and low sulphur are accurate, precise and have a good linearity.
It has an air flow checkout gear. The test process realized unattended operation.
Networking and the balance interlocking is possible.


Main features of SDS Series Coulometry Sulphur Analyzers:

The test results are accurate without secondary correction, which stands for the highest level of technology of Coulometry Sulphur Analyzers

The influences that secondary correction affects results:
Coulometry or Infrared Sulphur Analyzers need to be corrected for system deviation (First correction) and nonlinear index, during which 5 to 7 standard samples of different standard values are needed tested several times to form a calibration curve. It has proved that with the increase times of correction, it might lead to fantastic deviation results of the test data.

Dispensed with secondary correction, they can provide customers with the following experience:
Omitted the operating procedure of secondary correction, the debugging and operation of the instrument are easy.
The results are linear and accurate.
They can ensure accurate test results even the sulphur content of the coal sample is unknown.