Hunan Sundy Science and Technology Development Co., ltd
Calorimeters Series
SDC311 Calorimeter

SDC313 Calorimeter
SDC5015 Calorimeter

SDACM4000 Calorimeter




Proximate Analyzer
SDLA709 Proximate Analyzer
 
SDLA618 Proximate Analyzer
SDTGA5000 Proximate
  Analyzer
SDTGA308b Moisture Tester
SDTGA300c Moisture Tester
SDDH315 Blast Drying Oven
 
SDTGA100 Ash-Volatile
  Analyzer



Elemental Analyzer

SDCH235 Infrared Carbon
  and Hydrogen Analyzer
SDS212 Infrared Sulphur
  Analyzer
SDS616 Sulphur Analyzer
SDS601 Sulphur Analyzer
SDS516 Sulphur Analyzer
SDS-IVa Sulphur Analyzer


Ash Fusion Tester

SDAF 2000d Ash Fusion Tester







HOME > Calorimeters
SDC311 Calorimeter
 

Standard layout:
 SDC311 mainframe, dedicated water tank, Lenovo computer, Laser printer

Applicable Scope:
 It is applicable to measure the calorific value of coal, coke, petroleum, cement black meal and other combustibles.

Quality Certification:
 ASTM D 5865-2007a     Standard Test Method for Gross Calorific Value of Coal and Coke
 GB/T213-2008         Determination of calorific value of coal

Technical parameter:

Single Complete Testing Duration

<11 min

Precision

RSD≤0.1%

Stability

Heat Capacity Variation in 3 months≤0.20 %

Ambient Temperature

The test results confirm to demands when temperature during(10-30)℃

Accuracy

The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid .

Max Test Range

42000J /g

Temperature Resolution

0.0001 K

Sample Weight

0.5-1.5g

the Water Weight of External Barrel

40kg

New type of Oxygen Bomb

Yes

Oxygen Bomb 、 Identification

Automatic

CAN Bus Interface

Yes

Self-diagnostic Function

Yes

Complete Appliance Crust Shaped

Yes

Max Power

1.5kW

Voltage

AC220±10 ﹪ 50Hz±1Hz

Mainframe Size

432×560× 393mm

Net Weight

60kg




Main features of SDC Series Calorimeters:

 
The test results are fast, accurate and steady, and will not be affected by the fluctuation of the ambient temperature.

All measured data are real and reliable. Software correction is no need.
Highly automated instrument; can automatically recognize oxygen bomb, fix the quality of water, control temperature
  and carry out the test.
Strong adaptive capacity to environment; the testing results will not be affected by the fluctuation of the ambient
  temperature.
The isothermal points with helix tube technology (patent number 200610031417.X , 200610031414.6 ) realized
  temperature consensus of every part of the external barrel and barrelhead quickly, temperature of any fixed point can
  exactly represent that of the external barrel and barrelhead, making sure the test results are accurate.
The application of power contravariance and purification technology makes sure the instrument will not be affected by
  large variation of power voltage or power frequency.
Simple installation and debugging, easy to control.
Multiple controls by one computer and the inter-testing activity will not mutually affect.
Dada processing works in parallel with testing; easy for the users to look up test data.
Networking and the balance interlocking are possible.